External Cladding: Jointed 75mm Compleo Panel
External Cladding Top Hats: Topspan 61 (0.75BMT) or Knauf Top Hat 35 (0.75BMT)
Moisture Barrier: Breathable wall wrap
Frame: Minimum 92mm 1.15 BMT steel stud
Wall Insulation: Minimum R2.0 Earthwool

Internal Lining: As per table

System Number Acoustic Rating Rw (Rw+Ctr)
Acoustic Report 5008-17
FRL From Outside
Fire Report FAR 4395
FRL From Inside
Fire Report FAR 4395
Internal lining System Image
KCEH1 55 (48) 120/120/120 NA 13mm MastaShield exterior interior wall system Australia
KCEH2 55 (49) 120/120/120 60/60/60 16mm FireShield exterior interior wall system Australia
KCEH3 57 (52) 120/120/120 90/90/90 2 x 13mm FireShield exterior interior wall system Australia
KCEH4 58 (52) 120/120/120 120/120/120 2 x 16mm FireShield exterior interior wall system Australia

Table Notes:
1. FRL is unaffected by the insulation.
2. The Structural Adequacy component of the FRL refers to the stud.
3. MastaShield may be substituted with, 10mm SoundShield, 13mm WaterShield or 10mm Opal.
4. FireShield may be substituted with TruRock of the same thickness.